Medical Supplies

Categories

Product Brochure

For all our medical supplies and devices, please download the brochure

Point of care products

  • nova-biomedical-allegro-point-of-care-medical-device

    Allegro Blood Analyser

    Allegro is a compact, point-of-care (POC) analyzer that features a clinically important menu of 12 measured and individually selectable tests, plus 6 calculated tests. All tests are measured with disposable, ready-to-use cartridges or test strips, and are easily performed by nontechnical personnel.

    Allegro uses a very small capillary blood drop for all blood tests, which eliminates the need for venepuncture or a trained phlebotomist. With cartridge test times of 6 to 9 minutes and the ability to measure two cartridges simultaneously, Allegro provides rapid results. Having results during the patient visit—not after—is more effective for patient/clinician meetings; reduces off ice calls, letters, and follow-up visits; and improves patient compliance with care recommendations.

  • STAT EMS

    Stat EMS can measure lactate, hematocrit, hemoglobin, glucose, and ketone from a capillary blood drop. Results are available in seconds by using single-use biosensors and portable meters. Stat EMS offers simple, fast, and accurate testing in the field. Two meter systems are available. One provides patient data storage plus wireless connectivity to external data managers, the other provides data storage only.

    Test Menu

    Stat EMS provides important tests to help patient assessment, and emergency treatment. These tests can also help determine the appropriate transport site for patients with trauma, sepsis, or other specialized needs.

    Fingerstick Sampling

    Using capillary samples as small as 0.6 μL, Stat EMS provides fast and easy testing for high-stress medical situations. Capillary sampling and testing with Stat EMS is as easy as glucose self-testing performed by patients with diabetes. It eliminates the time and costs of a venipuncture, including the tourniquet, needle, vacutainer, and transfer pipette—as well as finding a suitable vein.

  • nova-biomedical-lac-hb-hct-point-of-care-medical-device

    StatStrip® LAC/Hb/Hct

    Fingerstick Capillary Blood Testing for Lactate, Hb, and Hct

    The StatStrip Lactate and Hemoglobin/Hematocrit Meter system (StatStrip LAC/Hb/Hct) is a handheld, easy-to-use meter system that measures LAC, Hb and Hct at the point-of-care using two disposable biosensors and tiny capillary blood samples for all tests. StatStrip’s lactate biosensor provides lab-like accuracy in just 13 seconds from 0.6 microliters of capillary blood. StatStrip’s Hb/Hct biosensor accurately measures – not calculates – both Hb and Hct in 40 seconds from a 1.6 microliter capillary sample.

  • nova-biomedical-lactate-meters-point-of-care-medical-device

    StatStrip® Lactate and StatStrip Xpress® Lactate Systems

    The StatStrip Lactate Hospital Meter System is a handheld point-of-care testing system that brings lactate testing directly to the patient’s bedside.

    Lactate is currently measured on blood gas analyzers, which creates numerous problems for bedside testing. Blood gas analyzers require anaerobic arterial samples, large sample volumes (100-200 microliters), and long analysis times (up to 2.5 minutes).

    In addition, blood gas analyzers are complex to operate, fixed in location, and expensive to purchase and use for serial lactate testing.

    StatStrip Lactate provides the fastest turnaround time possible (13 seconds), on the smallest whole blood sample (0.6 microliters), and can be easily operated by medical and nursing staff. StatStrip Lactate is a very low-cost device that makes lactate testing practical and affordable in any size ED, ICU, or medical unit. It is fully connectable to a hospital’s IT system through NovaNet.

    The StatStrip Lactate Hospital Meter System is a handheld point-of-care testing system that brings lactate testing directly to the patient’s bedside.

    Lactate is currently measured on blood gas analyzers, which creates numerous problems for bedside testing. Blood gas analyzers require anaerobic arterial samples, large sample volumes (100-200 microliters), and long analysis times (up to 2.5 minutes).

    In addition, blood gas analyzers are complex to operate, fixed in location, and expensive to purchase and use for serial lactate testing.

    StatStrip Lactate provides the fastest turnaround time possible (13 seconds), on the smallest whole blood sample (0.6 microliters), and can be easily operated by medical and nursing staff. StatStrip Lactate is a very low-cost device that makes lactate testing practical and affordable in any size ED, ICU, or medical unit. It is fully connectable to a hospital’s IT system through NovaNet.

  • StatStrip® and StatStrip Xpress®2 Glucose/Ketone Meters

    The most extensively studied and proven glucose measurement technology

    In addition to studies submitted to the FDA, 168 other independent studies over the last eight years—including 53 critical care studies—have found no clinically significant interferences for StatStrip’s measurement technology. This is a statement that no other glucose meter manufacturer can make. StatStrip and StatStrip Xpress2 are the world’s most extensively studied and proven glucose test. It has been proven to be safe and effective for use throughout all hospital and professional healthcare settings including critical care.

  • nova-biomedical-glucose-point-of-care-medical-device

    StatStrip® and StatStrip Xpress®2 Glucose Meters

    The only glucose meters cleared by US FDA and Health Canada for use with all patients, including critically ill

    Because of the unacceptably high rate of adverse patient events, including deaths, linked to the point-of-care (POC) use of glucose meters within hospitals, there is a recognized need for more accuracy and better performance standards for POC glucose testing in hospitals, particularly in intensive care settings.

    StatStrip is designed specifically to measure and correct for clinical interferences that can be present in critically ill patients.

    Proven safety and accuracy

    • In one study of over 17,300 capillary results from critically ill patients that were compared to lab results
    • In another study of 1,698 arterial and venous results from critically ill patients with over 257 medical conditions were compared to lab results
    • Improved accuracy results in less insulin misdosing and better outcomes for critically ill patients

    Use of any other meter with critically ill patients is considered off label in the U.S. by the FDA and high complexity testing under CLIA

    Use of any other glucose meter with critically ill patients is off label
    StatStrip is FDA cleared and CLIA waived for use throughout all hospital and all professional healthcare settings including critical care. Use of any other glucose meter with critically ill patients is considered off-label in the U.S. by the FDA and high complexity testing under CLIA.

    The personnel testing requirements for off-label use are very demanding and limit who can perform testing. In addition, a hospital must obtain patient consent to perform off-label testing.

    The most extensively studied and proven glucose measurement technology
    In addition to the studies submitted to the FDA, over 200 independent studies including 53 critical care studies—have found no clinically significant interferences for StatStrip. This is a statement that no other glucose meter manufacturer can make.

  • nova-biomedical-hb-hct-point-of-care-medical-device

    StatStrip® Hemoglobin and Hematocrit

    Only Point-of-Care (POC) Meter to Measure Both Hb and Hct

    The StatStrip Hemoglobin and Hematocrit Meter System (StatStrip Hb/Hct) is the only POC system to provide anemia screening and monitoring with measured, not calculated, Hb and Hct tests. This important breakthrough is possible because of new, patented electrochemical technologies developed by Nova Biomedical. Along with tiny, fingerstick capillary samples (1.6 µL) and results in 40 seconds, StatStrip Hb/Hct improves clinical decision making at the point of care.

  • nova-biomedical-creatinine-point-of-care-medical-device

    StatSensor® and StatSensor Xpress™ Creatinine and eGFR Meters

    The StatSensor Creatinine Hospital Meter System is a handheld analyzer and miniaturized, single-use biosensor for whole blood creatinine testing. StatSensor Creatinine incorporates patented Multi-Well™ technology. StatSensor Creatinine’s advanced technology enables simple, rapid, and accurate assessment of renal function by fingerstick capillary blood sampling at the point of care.

  • Nova Max® Plus™

    The Best Overall Glucose Monitor

    Nova Max Plus incorporates advanced technology for accurate and precise self-monitoring of blood glucose and ketones by people with diabetes. Nova Max Plus has the most comprehensive features for fast, easy, and error-free blood glucose and ketone monitoring.

    Glucose and Ketones on the Same Monitor

    The Nova Max Plus Glucose Meter automatically converts to a ketone meter by inserting the Nova Max Plus Ketone strip.

    Why Ketone Measurements Are Important

    Diabetic Ketoacidosis (DKA) is a life-threatening metabolic complication of diabetes with a mortality rate of 2%-10%.1 DKA is the leading cause of hospitalization, morbidity, and death in children with Type 1 diabetes.2 The use of a blood test for early detection of increased blood ketone levels can help to avert DKA.3-5 According to the ADA, blood ketone testing should be performed on sick days and whenever glucose is greater than 250-300 mg/dL.

  • Healgen 500 Urine Analyser

    The Urine Analyzer is intended to be used with the urinalysis strips for clinical urine testing.

    The urinalysis strip could detect Urobilinogen, Bilirubin, Ketone (acetoacetic acid), Occult blood, Protein, Nitrite, Leukocytes, Glucose, Specific Gravity, pH, Vitamin C and Microalbumin in human urine.

This website uses cookies to ensure you get the best experience on our website. Please accept to continue or refer to Terms of Use here.